Mark what is already defined. The checker identifies missing quote inputs; it does not select a thermal process or approve a specification.
Drawing number and current revision Not defined Defined
Material grade, standard and incoming condition Not defined Defined
Target property, hardness range and location Not defined Defined
Controlling process specification and revision Not defined Defined
Part condition when treatment starts Not defined Defined
Datum, distortion and final-dimension limits Not defined Defined
Post-treatment machining or grinding Not defined Defined
Test method, scale, location and sampling Not defined Defined
Acceptance criteria and deviation authority Not defined Defined
Required reports and traceability fields Not defined Defined
Quantity, lot split and requested delivery Not defined Defined
Packaging, marking and change notification Not defined Defined
A complete input package makes quotes easier to compare. Final process selection, capability, acceptance and release still require drawing review and written agreement.